{"id":4613,"date":"2026-08-11T15:38:38","date_gmt":"2026-08-11T07:38:38","guid":{"rendered":"https:\/\/oretonstorage.com\/?p=4613"},"modified":"2026-08-11T15:38:38","modified_gmt":"2026-08-11T07:38:38","slug":"ssd-write-amplification-and-nand-flash-endurance","status":"publish","type":"post","link":"https:\/\/oretonstorage.com\/ko\/%eb%b8%94%eb%a1%9c%ea%b7%b8\/ssd-write-amplification-and-nand-flash-endurance","title":{"rendered":"SSD Write Amplification and NAND Flash Endurance"},"content":{"rendered":"<h2 class=\"PDq2pG_selectionAnchorContainer\" data-section-id=\"13ax1s5\" data-start=\"219\" data-end=\"234\">Introduction<\/h2>\n<p data-start=\"236\" data-end=\"453\">SSD endurance is often represented by metrics such as <strong data-start=\"290\" data-end=\"317\">TBW (Terabytes Written)<\/strong> or DWPD. However, the amount of data written by the host is not necessarily equal to the amount of data actually written to NAND Flash.<img decoding=\"async\" class=\" wp-image-4616 alignright\" src=\"https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/08\/\u5fae\u4fe1\u56fe\u7247_2026-08-11_153224_408-773x1030.png\" alt=\"\" width=\"357\" height=\"476\" srcset=\"https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/08\/\u5fae\u4fe1\u56fe\u7247_2026-08-11_153224_408-773x1030.png 773w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/08\/\u5fae\u4fe1\u56fe\u7247_2026-08-11_153224_408-225x300.png 225w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/08\/\u5fae\u4fe1\u56fe\u7247_2026-08-11_153224_408-768x1024.png 768w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/08\/\u5fae\u4fe1\u56fe\u7247_2026-08-11_153224_408-1152x1536.png 1152w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/08\/\u5fae\u4fe1\u56fe\u7247_2026-08-11_153224_408-1536x2048.png 1536w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/08\/\u5fae\u4fe1\u56fe\u7247_2026-08-11_153224_408-9x12.png 9w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/08\/\u5fae\u4fe1\u56fe\u7247_2026-08-11_153224_408-800x1067.png 800w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/08\/\u5fae\u4fe1\u56fe\u7247_2026-08-11_153224_408-scaled.png 1920w\" sizes=\"(max-width: 357px) 100vw, 357px\" \/><\/p>\n<p data-start=\"455\" data-end=\"514\">This difference is closely related to a key storage metric:<\/p>\n<p data-start=\"516\" data-end=\"553\"><strong data-start=\"516\" data-end=\"553\">Write Amplification Factor (WAF).<\/strong><\/p>\n<p data-start=\"555\" data-end=\"712\">Write amplification describes the relationship between the amount of data written by the host system and the amount of data ultimately written to NAND Flash.<\/p>\n<p data-start=\"714\" data-end=\"745\">A simplified representation is:<\/p>\n<p data-start=\"747\" data-end=\"780\"><strong data-start=\"747\" data-end=\"780\">WAF = NAND Write \/ Host Write<\/strong><\/p>\n<p data-start=\"782\" data-end=\"908\">For example, if a host writes 100 GB of data but the NAND receives 150 GB of actual writes, the write amplification factor is:<\/p>\n<p data-start=\"910\" data-end=\"923\"><strong data-start=\"910\" data-end=\"923\">WAF = 1.5<\/strong><\/p>\n<p data-start=\"925\" data-end=\"1033\">A higher WAF means more NAND program\/erase activity, which can increase wear and reduce available endurance.<\/p>\n<p data-start=\"1035\" data-end=\"1196\">For SSD manufacturers, understanding and controlling write amplification is therefore an important part of SSD performance, endurance, and firmware optimization.<\/p>\n<hr data-start=\"1198\" data-end=\"1201\" \/>\n<h1 data-section-id=\"wznh0\" data-start=\"1203\" data-end=\"1237\">What Causes Write Amplification?<\/h1>\n<p data-start=\"1239\" data-end=\"1323\">Write amplification is mainly related to the way NAND Flash stores and manages data.<\/p>\n<p data-start=\"1325\" data-end=\"1417\">NAND Flash cannot simply overwrite existing data in the same way as traditional hard drives.<\/p>\n<p data-start=\"1419\" data-end=\"1544\">Instead, data is generally written to available pages, while outdated data remains until the corresponding blocks are erased.<\/p>\n<p data-start=\"1546\" data-end=\"1590\">This creates additional internal operations.<\/p>\n<p data-start=\"1592\" data-end=\"1624\">A typical process can look like:<\/p>\n<p style=\"text-align: center\" data-start=\"1626\" data-end=\"1640\"><strong data-start=\"1626\" data-end=\"1640\">Host Write<\/strong><\/p>\n<p style=\"text-align: center\" data-start=\"1642\" data-end=\"1643\">\u2193<\/p>\n<p style=\"text-align: center\" data-start=\"1645\" data-end=\"1668\"><strong data-start=\"1645\" data-end=\"1668\">Data stored in NAND<\/strong><\/p>\n<p style=\"text-align: center\" data-start=\"1670\" data-end=\"1671\">\u2193<\/p>\n<p style=\"text-align: center\" data-start=\"1673\" data-end=\"1701\"><strong data-start=\"1673\" data-end=\"1701\">Old data becomes invalid<\/strong><\/p>\n<p style=\"text-align: center\" data-start=\"1703\" data-end=\"1704\">\u2193<\/p>\n<p style=\"text-align: center\" data-start=\"1706\" data-end=\"1728\"><strong data-start=\"1706\" data-end=\"1728\">Garbage Collection<\/strong><\/p>\n<p style=\"text-align: center\" data-start=\"1730\" data-end=\"1731\">\u2193<\/p>\n<p style=\"text-align: center\" data-start=\"1733\" data-end=\"1753\"><strong data-start=\"1733\" data-end=\"1753\">Valid data moved<\/strong><\/p>\n<p style=\"text-align: center\" data-start=\"1755\" data-end=\"1756\">\u2193<\/p>\n<p style=\"text-align: center\" data-start=\"1758\" data-end=\"1773\"><strong data-start=\"1758\" data-end=\"1773\">Block Erase<\/strong><\/p>\n<p style=\"text-align: center\" data-start=\"1775\" data-end=\"1776\">\u2193<\/p>\n<p style=\"text-align: center\" data-start=\"1778\" data-end=\"1811\"><strong data-start=\"1778\" data-end=\"1811\">Block becomes available again<\/strong><\/p>\n<p data-start=\"1813\" data-end=\"1902\">The additional movement of valid data is one of the major sources of write amplification.<\/p>\n<hr data-start=\"1904\" data-end=\"1907\" \/>\n<h1 data-section-id=\"6x9qk0\" data-start=\"1909\" data-end=\"1949\">NAND Flash Writes and Erase Operations<\/h1>\n<p data-start=\"1951\" data-end=\"2059\">Understanding NAND endurance requires understanding the relationship between <strong data-start=\"2028\" data-end=\"2058\">Program\/Erase (P\/E) cycles<\/strong>.<img decoding=\"async\" class=\" wp-image-4521 alignright\" src=\"https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/07\/\u5fae\u4fe1\u56fe\u7247_2026-06-16_175136_836-773x1030.png\" alt=\"\" width=\"386\" height=\"514\" srcset=\"https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/07\/\u5fae\u4fe1\u56fe\u7247_2026-06-16_175136_836-773x1030.png 773w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/07\/\u5fae\u4fe1\u56fe\u7247_2026-06-16_175136_836-225x300.png 225w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/07\/\u5fae\u4fe1\u56fe\u7247_2026-06-16_175136_836-768x1024.png 768w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/07\/\u5fae\u4fe1\u56fe\u7247_2026-06-16_175136_836-1152x1536.png 1152w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/07\/\u5fae\u4fe1\u56fe\u7247_2026-06-16_175136_836-1536x2048.png 1536w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/07\/\u5fae\u4fe1\u56fe\u7247_2026-06-16_175136_836-9x12.png 9w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/07\/\u5fae\u4fe1\u56fe\u7247_2026-06-16_175136_836-800x1067.png 800w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/07\/\u5fae\u4fe1\u56fe\u7247_2026-06-16_175136_836-scaled.png 1920w\" sizes=\"(max-width: 386px) 100vw, 386px\" \/><\/p>\n<p data-start=\"2061\" data-end=\"2113\">NAND Flash cells have a finite number of P\/E cycles.<\/p>\n<p data-start=\"2115\" data-end=\"2254\">Every time data is programmed into a NAND page and the corresponding block is eventually erased, the NAND cells experience additional wear.<\/p>\n<p data-start=\"2256\" data-end=\"2324\">The exact endurance depends on the NAND technology and architecture.<\/p>\n<p data-start=\"2326\" data-end=\"2392\">Different NAND types can have different endurance characteristics:<\/p>\n<ul data-start=\"2394\" data-end=\"2417\">\n<li data-section-id=\"1o4r04\" data-start=\"2394\" data-end=\"2399\">SLC<\/li>\n<li data-section-id=\"1o4bze\" data-start=\"2400\" data-end=\"2405\">MLC<\/li>\n<li data-section-id=\"1o4rqr\" data-start=\"2406\" data-end=\"2411\">TLC<\/li>\n<li data-section-id=\"1o4sl2\" data-start=\"2412\" data-end=\"2417\">QLC<\/li>\n<\/ul>\n<p data-start=\"2419\" data-end=\"2556\">As the number of bits stored per cell increases, storage density improves, but the electrical margins between states become more complex.<\/p>\n<p data-start=\"2558\" data-end=\"2630\">This makes NAND management increasingly important for SSD manufacturers.<\/p>\n<hr data-start=\"2632\" data-end=\"2635\" \/>\n<h1 data-section-id=\"7fdecb\" data-start=\"2637\" data-end=\"2681\">Write Amplification and Garbage Collection<\/h1>\n<p data-start=\"2683\" data-end=\"2756\"><strong data-start=\"2683\" data-end=\"2710\">Garbage Collection (GC)<\/strong> is essential for maintaining SSD performance.<\/p>\n<p data-start=\"2758\" data-end=\"2901\">When an SSD contains blocks with a mixture of valid and invalid pages, the controller needs to consolidate valid data before erasing the block.<\/p>\n<p data-start=\"2903\" data-end=\"2915\">For example:<\/p>\n<div class=\"relative w-full mt-4 mb-1\">\n<div class=\"\">\n<div class=\"contents\">\n<div class=\"relative\">\n<div class=\"h-full min-h-0 min-w-0\">\n<div class=\"h-full min-h-0 min-w-0\">\n<div class=\"border border-token-border-light border-radius-3xl corner-superellipse\/1.1 rounded-3xl\">\n<div class=\"h-full w-full border-radius-3xl bg-(--code-block-surface) corner-superellipse\/1.1 overflow-clip rounded-3xl [--code-block-surface:var(--bg-elevated-secondary)] dark:[--code-block-surface:var(--composer-surface-primary)] lxnfua_clipPathFallback\">\n<div class=\"pointer-events-none absolute end-1.5 top-1 z-2 md:end-2 md:top-1\"><\/div>\n<div class=\"relative\">\n<div class=\"pe-11 pt-3\">\n<div class=\"relative z-0 flex max-w-full\">\n<div id=\"code-block-viewer\" class=\"q9tKkq_viewer cm-editor z-10 light:cm-light dark:cm-light flex h-full w-full flex-col items-stretch \u037cs \u037c16\" dir=\"ltr\">\n<div class=\"cm-scroller\">\n<pre class=\"cm-content q9tKkq_readonly m-0\"><code>Block A\r\n\r\n[Valid] [Invalid] [Valid] [Invalid]<\/code><\/pre>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"\">\n<div class=\"\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p data-start=\"2975\" data-end=\"3043\">The controller may need to move the valid pages to another location:<\/p>\n<div class=\"relative w-full mt-4 mb-1\">\n<div class=\"\">\n<div class=\"contents\">\n<div class=\"relative\">\n<div class=\"h-full min-h-0 min-w-0\">\n<div class=\"h-full min-h-0 min-w-0\">\n<div class=\"border border-token-border-light border-radius-3xl corner-superellipse\/1.1 rounded-3xl\">\n<div class=\"h-full w-full border-radius-3xl bg-(--code-block-surface) corner-superellipse\/1.1 overflow-clip rounded-3xl [--code-block-surface:var(--bg-elevated-secondary)] dark:[--code-block-surface:var(--composer-surface-primary)] lxnfua_clipPathFallback\">\n<div class=\"pointer-events-none absolute end-1.5 top-1 z-2 md:end-2 md:top-1\"><\/div>\n<div class=\"relative\">\n<div class=\"pe-11 pt-3\">\n<div class=\"relative z-0 flex max-w-full\">\n<div id=\"code-block-viewer\" class=\"q9tKkq_viewer cm-editor z-10 light:cm-light dark:cm-light flex h-full w-full flex-col items-stretch \u037cs \u037c16\" dir=\"ltr\">\n<div class=\"cm-scroller\">\n<pre class=\"cm-content q9tKkq_readonly m-0\"><code>New Block\r\n\r\n[Valid] [Valid] [Empty] [Empty]<\/code><\/pre>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<div class=\"\">\n<div class=\"\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p data-start=\"3101\" data-end=\"3150\">The original block can then be erased and reused.<\/p>\n<p data-start=\"3152\" data-end=\"3250\">These additional data movements generate NAND writes that were not directly requested by the host.<\/p>\n<p data-start=\"3252\" data-end=\"3292\">This contributes to write amplification.<\/p>\n<hr data-start=\"3294\" data-end=\"3297\" \/>\n<h1 data-section-id=\"1n9aqe8\" data-start=\"3299\" data-end=\"3317\">The Role of TRIM<\/h1>\n<p data-start=\"3319\" data-end=\"3415\"><strong data-start=\"3319\" data-end=\"3327\">TRIM<\/strong> helps SSDs understand which data blocks are no longer required by the operating system.<\/p>\n<p data-start=\"3417\" data-end=\"3499\">Without TRIM, the SSD may not know that certain logical blocks have become unused.<\/p>\n<p data-start=\"3501\" data-end=\"3576\">With TRIM, the controller can identify invalid or unnecessary data earlier.<\/p>\n<p data-start=\"3578\" data-end=\"3595\">This can improve:<\/p>\n<ul data-start=\"3597\" data-end=\"3689\">\n<li data-section-id=\"ggqk7w\" data-start=\"3597\" data-end=\"3628\">Garbage collection efficiency<\/li>\n<li data-section-id=\"1yj7znx\" data-start=\"3629\" data-end=\"3648\">Write performance<\/li>\n<li data-section-id=\"68ujtt\" data-start=\"3649\" data-end=\"3671\">Available free space<\/li>\n<li data-section-id=\"10caiu6\" data-start=\"3672\" data-end=\"3689\">NAND management<\/li>\n<\/ul>\n<p data-start=\"3691\" data-end=\"3798\">Under suitable workloads, better information about unused data can help reduce unnecessary internal writes.<\/p>\n<hr data-start=\"3800\" data-end=\"3803\" \/>\n<h1 data-section-id=\"hgszo2\" data-start=\"3805\" data-end=\"3848\">Over-Provisioning and Write Amplification<\/h1>\n<p data-start=\"3850\" data-end=\"3905\"><strong data-start=\"3850\" data-end=\"3876\">Over-Provisioning (OP)<\/strong> is another important factor.<\/p>\n<p data-start=\"3907\" data-end=\"3988\">An SSD does not necessarily expose all of its physical NAND capacity to the user.<\/p>\n<p data-start=\"3990\" data-end=\"4057\">Some NAND capacity can be reserved for internal operations such as:<\/p>\n<ul data-start=\"4059\" data-end=\"4145\">\n<li data-section-id=\"4wfatn\" data-start=\"4059\" data-end=\"4079\">Garbage collection<\/li>\n<li data-section-id=\"7vtlzz\" data-start=\"4080\" data-end=\"4095\">Wear leveling<\/li>\n<li data-section-id=\"1y8nrxx\" data-start=\"4096\" data-end=\"4118\">Bad block management<\/li>\n<li data-section-id=\"lrndk5\" data-start=\"4119\" data-end=\"4129\">Metadata<\/li>\n<li data-section-id=\"pydynv\" data-start=\"4130\" data-end=\"4145\">Data movement<\/li>\n<\/ul>\n<p data-start=\"4147\" data-end=\"4235\">Additional available space gives the controller more flexibility when reorganizing data.<\/p>\n<p data-start=\"4237\" data-end=\"4360\">In many workloads, greater over-provisioning can help improve garbage collection efficiency and reduce write amplification.<\/p>\n<p data-start=\"4362\" data-end=\"4439\">This is particularly important in workloads involving frequent random writes.<\/p>\n<hr data-start=\"4441\" data-end=\"4444\" \/>\n<h1 data-section-id=\"p2td9h\" data-start=\"4446\" data-end=\"4478\">Sequential vs Random Workloads<\/h1>\n<p data-start=\"4480\" data-end=\"4554\">Workload characteristics have a significant impact on write amplification.<\/p>\n<h3 data-section-id=\"1if4aht\" data-start=\"4556\" data-end=\"4577\">Sequential Writes<\/h3>\n<p data-start=\"4579\" data-end=\"4672\">Sequential workloads generally allow the controller to write data in a more organized manner.<\/p>\n<p data-start=\"4674\" data-end=\"4716\">This can reduce unnecessary data movement.<\/p>\n<h3 data-section-id=\"1nck6fn\" data-start=\"4718\" data-end=\"4735\">Random Writes<\/h3>\n<p data-start=\"4737\" data-end=\"4831\">Random workloads can create fragmented blocks containing a mixture of valid and invalid pages.<\/p>\n<p data-start=\"4833\" data-end=\"4904\">This may require more internal data movement during garbage collection.<\/p>\n<p data-start=\"4906\" data-end=\"5007\">As a result, random-write workloads can generate higher write amplification under certain conditions.<\/p>\n<p data-start=\"5009\" data-end=\"5123\">This is one reason why SSD performance and endurance cannot be evaluated using sequential benchmark results alone.<\/p>\n<hr data-start=\"5125\" data-end=\"5128\" \/>\n<h1 data-section-id=\"1tq3ssj\" data-start=\"5130\" data-end=\"5162\">The Role of the SSD Controller<\/h1>\n<p data-start=\"5164\" data-end=\"5246\">The SSD controller is responsible for managing much of the internal NAND behavior.<\/p>\n<p data-start=\"5248\" data-end=\"5281\">Its responsibilities can include:<\/p>\n<ul data-start=\"5283\" data-end=\"5410\">\n<li data-section-id=\"ftnbta\" data-start=\"5283\" data-end=\"5306\">NAND Flash management<\/li>\n<li data-section-id=\"1m4ym5n\" data-start=\"5307\" data-end=\"5327\">Garbage Collection<\/li>\n<li data-section-id=\"17aujcv\" data-start=\"5328\" data-end=\"5343\">Wear Leveling<\/li>\n<li data-section-id=\"1o4iq5\" data-start=\"5344\" data-end=\"5349\">ECC<\/li>\n<li data-section-id=\"s8f985\" data-start=\"5350\" data-end=\"5372\">Bad Block Management<\/li>\n<li data-section-id=\"14p3vpn\" data-start=\"5373\" data-end=\"5395\">SLC Cache Management<\/li>\n<li data-section-id=\"2ops2c\" data-start=\"5396\" data-end=\"5410\">Data Mapping<\/li>\n<\/ul>\n<p data-start=\"5412\" data-end=\"5498\">The controller determines how efficiently data is organized and moved within the NAND.<\/p>\n<p data-start=\"5500\" data-end=\"5630\">A well-designed controller and firmware combination can improve internal data management and help control unnecessary NAND writes.<\/p>\n<hr data-start=\"5632\" data-end=\"5635\" \/>\n<h1 data-section-id=\"1yakkn2\" data-start=\"5637\" data-end=\"5668\">Firmware Optimization Matters<\/h1>\n<p data-start=\"5670\" data-end=\"5724\">Hardware alone does not determine write amplification.<\/p>\n<p data-start=\"5726\" data-end=\"5768\"><strong data-start=\"5726\" data-end=\"5749\">Firmware algorithms<\/strong> play a major role.<\/p>\n<p data-start=\"5770\" data-end=\"5791\">SSD firmware manages:<\/p>\n<ul data-start=\"5793\" data-end=\"5929\">\n<li data-section-id=\"1bx4dj3\" data-start=\"5793\" data-end=\"5830\">Logical-to-physical address mapping<\/li>\n<li data-section-id=\"4wfatn\" data-start=\"5831\" data-end=\"5851\">Garbage collection<\/li>\n<li data-section-id=\"7vtlzz\" data-start=\"5852\" data-end=\"5867\">Wear leveling<\/li>\n<li data-section-id=\"h6q07c\" data-start=\"5868\" data-end=\"5884\">Cache behavior<\/li>\n<li data-section-id=\"1cvfrz1\" data-start=\"5885\" data-end=\"5902\">NAND allocation<\/li>\n<li data-section-id=\"mi3l6d\" data-start=\"5903\" data-end=\"5929\">Background data movement<\/li>\n<\/ul>\n<p data-start=\"5931\" data-end=\"6000\">Poorly optimized firmware can cause excessive internal data movement.<\/p>\n<p data-start=\"6002\" data-end=\"6097\">Well-designed firmware can better coordinate these operations according to workload conditions.<\/p>\n<p data-start=\"6099\" data-end=\"6177\">This is particularly important when designing SSDs for different applications.<\/p>\n<p data-start=\"6179\" data-end=\"6332\">A consumer SSD, gaming SSD, industrial SSD, and enterprise SSD may face very different workloads and therefore require different optimization strategies.<\/p>\n<hr data-start=\"6334\" data-end=\"6337\" \/>\n<h1 data-section-id=\"cwkpqx\" data-start=\"6339\" data-end=\"6368\">Write Amplification and TBW<\/h1>\n<p data-start=\"6370\" data-end=\"6417\">TBW is commonly used to describe SSD endurance.<\/p>\n<p data-start=\"6419\" data-end=\"6468\">However, TBW should not be interpreted simply as:<\/p>\n<p data-start=\"6470\" data-end=\"6533\"><strong data-start=\"6470\" data-end=\"6533\">&#8220;The SSD can physically write exactly this amount of data.&#8221;<\/strong><\/p>\n<p data-start=\"6535\" data-end=\"6574\">The actual NAND workload includes both:<\/p>\n<p data-start=\"6576\" data-end=\"6591\"><strong data-start=\"6576\" data-end=\"6591\">Host Writes<\/strong><\/p>\n<p data-start=\"6593\" data-end=\"6596\">and<\/p>\n<p data-start=\"6598\" data-end=\"6622\"><strong data-start=\"6598\" data-end=\"6622\">Internal NAND Writes<\/strong><\/p>\n<p data-start=\"6624\" data-end=\"6663\">Write amplification connects these two.<\/p>\n<p data-start=\"6665\" data-end=\"6677\">For example:<\/p>\n<p data-start=\"6679\" data-end=\"6696\">If a host writes:<\/p>\n<p data-start=\"6698\" data-end=\"6706\"><strong data-start=\"6698\" data-end=\"6706\">1 TB<\/strong><\/p>\n<p data-start=\"6708\" data-end=\"6739\">and the SSD generates a WAF of:<\/p>\n<p data-start=\"6741\" data-end=\"6748\"><strong data-start=\"6741\" data-end=\"6748\">1.5<\/strong><\/p>\n<p data-start=\"6750\" data-end=\"6785\">the NAND may receive approximately:<\/p>\n<p data-start=\"6787\" data-end=\"6797\"><strong data-start=\"6787\" data-end=\"6797\">1.5 TB<\/strong><\/p>\n<p data-start=\"6799\" data-end=\"6809\">of writes.<\/p>\n<p data-start=\"6811\" data-end=\"6905\">Therefore, controlling write amplification can help make more efficient use of NAND endurance.<\/p>\n<hr data-start=\"6907\" data-end=\"6910\" \/>\n<h1 data-section-id=\"1skjyuz\" data-start=\"6912\" data-end=\"6941\">Wear Leveling and Endurance<\/h1>\n<p data-start=\"6943\" data-end=\"7009\">Write amplification is only one part of NAND endurance management.<\/p>\n<p data-start=\"7011\" data-end=\"7058\"><strong data-start=\"7011\" data-end=\"7028\">Wear Leveling<\/strong> also plays an important role.<\/p>\n<p data-start=\"7060\" data-end=\"7169\">Without effective wear leveling, some NAND blocks could experience significantly more P\/E cycles than others.<\/p>\n<p data-start=\"7171\" data-end=\"7246\">The controller can distribute data across NAND blocks to help balance wear.<\/p>\n<p data-start=\"7248\" data-end=\"7267\">The combination of:<\/p>\n<ul data-start=\"7269\" data-end=\"7361\">\n<li data-section-id=\"17aujcv\" data-start=\"7269\" data-end=\"7284\">Wear Leveling<\/li>\n<li data-section-id=\"1m4ym5n\" data-start=\"7285\" data-end=\"7305\">Garbage Collection<\/li>\n<li data-section-id=\"m17ujm\" data-start=\"7306\" data-end=\"7325\">Over-Provisioning<\/li>\n<li data-section-id=\"1j4dadm\" data-start=\"7326\" data-end=\"7332\">TRIM<\/li>\n<li data-section-id=\"1o4iq5\" data-start=\"7333\" data-end=\"7338\">ECC<\/li>\n<li data-section-id=\"s8f985\" data-start=\"7339\" data-end=\"7361\">Bad Block Management<\/li>\n<\/ul>\n<p data-start=\"7363\" data-end=\"7407\">creates a complete NAND management strategy.<\/p>\n<hr data-start=\"7409\" data-end=\"7412\" \/>\n<h1 data-section-id=\"sqndlv\" data-start=\"7414\" data-end=\"7448\">Why NAND Selection Still Matters<\/h1>\n<p data-start=\"7450\" data-end=\"7534\">Firmware optimization cannot completely compensate for inappropriate NAND selection.<\/p>\n<p data-start=\"7536\" data-end=\"7608\">Different NAND components can have different characteristics, including:<\/p>\n<ul data-start=\"7610\" data-end=\"7711\">\n<li data-section-id=\"1ndjl0w\" data-start=\"7610\" data-end=\"7619\">Density<\/li>\n<li data-section-id=\"19ihr0p\" data-start=\"7620\" data-end=\"7631\">Endurance<\/li>\n<li data-section-id=\"3v9f2o\" data-start=\"7632\" data-end=\"7645\">Performance<\/li>\n<li data-section-id=\"8jifgs\" data-start=\"7646\" data-end=\"7673\">P\/E cycle characteristics<\/li>\n<li data-section-id=\"1f6q896\" data-start=\"7674\" data-end=\"7691\">Interface speed<\/li>\n<li data-section-id=\"c4if8w\" data-start=\"7692\" data-end=\"7711\">Die configuration<\/li>\n<\/ul>\n<p data-start=\"7713\" data-end=\"7839\">For SSD manufacturers, the relationship between <strong data-start=\"7761\" data-end=\"7799\">NAND Flash + Controller + Firmware<\/strong> must be evaluated as a complete system.<\/p>\n<p data-start=\"7841\" data-end=\"7948\">The same controller can behave differently depending on the NAND configuration and firmware implementation.<\/p>\n<p data-start=\"7950\" data-end=\"8029\">This is why NAND qualification is an important part of SSD product development.<\/p>\n<hr data-start=\"8031\" data-end=\"8034\" \/>\n<h1 data-section-id=\"1nhr8rb\" data-start=\"8036\" data-end=\"8072\">Oreton&#8217;s Approach to SSD Endurance<\/h1>\n<p data-start=\"8074\" data-end=\"8148\">At Oreton, SSD endurance is considered at the component and system levels.<img decoding=\"async\" class=\" wp-image-4506 alignright\" src=\"https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/07\/2023.7.17-773x1030.png\" alt=\"\" width=\"468\" height=\"624\" srcset=\"https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/07\/2023.7.17-773x1030.png 773w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/07\/2023.7.17-225x300.png 225w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/07\/2023.7.17-768x1024.png 768w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/07\/2023.7.17-1152x1536.png 1152w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/07\/2023.7.17-1536x2048.png 1536w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/07\/2023.7.17-9x12.png 9w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/07\/2023.7.17-800x1067.png 800w, https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/07\/2023.7.17-scaled.png 1920w\" sizes=\"(max-width: 468px) 100vw, 468px\" \/><\/p>\n<p data-start=\"8150\" data-end=\"8212\">Our SSD development process evaluates the interaction between:<\/p>\n<p data-start=\"8214\" data-end=\"8228\"><strong data-start=\"8214\" data-end=\"8228\">NAND Flash<\/strong><\/p>\n<ul data-start=\"8230\" data-end=\"8231\">\n<li data-section-id=\"3szy\" data-start=\"8230\" data-end=\"8231\"><\/li>\n<\/ul>\n<p data-start=\"8233\" data-end=\"8251\"><strong data-start=\"8233\" data-end=\"8251\">SSD Controller<\/strong><\/p>\n<ul data-start=\"8253\" data-end=\"8254\">\n<li data-section-id=\"3szy\" data-start=\"8253\" data-end=\"8254\"><\/li>\n<\/ul>\n<p data-start=\"8256\" data-end=\"8268\"><strong data-start=\"8256\" data-end=\"8268\">Firmware<\/strong><\/p>\n<ul data-start=\"8270\" data-end=\"8271\">\n<li data-section-id=\"3szy\" data-start=\"8270\" data-end=\"8271\"><\/li>\n<\/ul>\n<p data-start=\"8273\" data-end=\"8295\"><strong data-start=\"8273\" data-end=\"8295\">Thermal Management<\/strong><\/p>\n<ul data-start=\"8297\" data-end=\"8298\">\n<li data-section-id=\"3szy\" data-start=\"8297\" data-end=\"8298\"><\/li>\n<\/ul>\n<p data-start=\"8300\" data-end=\"8328\"><strong data-start=\"8300\" data-end=\"8328\">Workload Characteristics<\/strong><\/p>\n<p data-start=\"8330\" data-end=\"8498\">Rather than focusing only on peak sequential performance, SSD validation also considers sustained workloads, NAND behavior, thermal conditions, and long-term stability.<\/p>\n<p data-start=\"8500\" data-end=\"8684\">For products such as the <strong data-start=\"8525\" data-end=\"8541\">Oreton N7000<\/strong>, careful matching of PCIe 4.0 NAND, controller, firmware, and thermal design helps balance high performance with reliable long-term operation.<\/p>\n<p data-start=\"8686\" data-end=\"8817\">For OEM and distribution customers, this approach provides a more complete understanding of SSD quality than benchmark speed alone.<\/p>\n<hr data-start=\"8819\" data-end=\"8822\" \/>\n<h1 data-section-id=\"fsb6xx\" data-start=\"8824\" data-end=\"8836\">Conclusion<\/h1>\n<p data-start=\"8838\" data-end=\"8908\">Write amplification is one of the hidden factors behind SSD endurance.<\/p>\n<p data-start=\"8910\" data-end=\"9129\">The amount of data written by the host does not always equal the amount of data written to NAND Flash. Garbage collection, wear leveling, data movement, and other internal operations can generate additional NAND writes.<\/p>\n<p data-start=\"9131\" data-end=\"9198\">Managing these operations efficiently requires cooperation between:<\/p>\n<p data-start=\"9200\" data-end=\"9280\"><strong data-start=\"9200\" data-end=\"9280\">NAND Flash + Controller + Firmware + Over-Provisioning + Workload Management<\/strong><\/p>\n<p data-start=\"9282\" data-end=\"9464\">For SSD manufacturers, controlling write amplification is therefore not simply a performance optimization\u2014it is an important part of NAND endurance and long-term product reliability.<\/p>\n<p data-start=\"9466\" data-end=\"9535\">A high-quality SSD is not defined only by how fast it can write data.<\/p>\n<p data-start=\"9537\" data-end=\"9620\" data-is-last-node=\"\" data-is-only-node=\"\"><strong data-start=\"9537\" data-end=\"9620\" data-is-last-node=\"\">It is also defined by how efficiently it manages every write behind the scenes.<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Introduction SSD endurance is often represented by metrics such as TBW (Terabytes Written) or DWPD. However, the amount of data written by the host is not necessarily equal to the amount of data actually written to NAND Flash. This difference is closely related to a key storage metric: Write Amplification Factor (WAF). Write amplification describes&#8230;<\/p>","protected":false},"author":3,"featured_media":4615,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-4613","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>SSD Write Amplification and NAND Flash Endurance -<\/title>\n<meta name=\"description\" content=\"Explore SSD write amplification, NAND flash endurance, garbage collection, wear leveling, over-provisioning, and the role of controllers and firmware in SSD reliability.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/oretonstorage.com\/ko\/\ube14\ub85c\uadf8\/ssd-write-amplification-and-nand-flash-endurance\" \/>\n<meta property=\"og:locale\" content=\"ko_KR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"SSD Write Amplification and NAND Flash Endurance -\" \/>\n<meta property=\"og:description\" content=\"Explore SSD write amplification, NAND flash endurance, garbage collection, wear leveling, over-provisioning, and the role of controllers and firmware in SSD reliability.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/oretonstorage.com\/ko\/\ube14\ub85c\uadf8\/ssd-write-amplification-and-nand-flash-endurance\" \/>\n<meta property=\"article:published_time\" content=\"2026-08-11T07:38:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/08\/BCO.82ef9134-0979-4620-b8e8-122bdc3088a0-1030x687.png\" \/>\n\t<meta property=\"og:image:width\" content=\"1030\" \/>\n\t<meta property=\"og:image:height\" content=\"687\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Echo\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\uae00\uc4f4\uc774\" \/>\n\t<meta name=\"twitter:data1\" content=\"Echo\" \/>\n\t<meta name=\"twitter:label2\" content=\"\uc608\uc0c1 \ub418\ub294 \ud310\ub3c5 \uc2dc\uac04\" \/>\n\t<meta name=\"twitter:data2\" content=\"7\ubd84\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/oretonstorage.com\\\/blog\\\/ssd-write-amplification-and-nand-flash-endurance#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/oretonstorage.com\\\/blog\\\/ssd-write-amplification-and-nand-flash-endurance\"},\"author\":{\"name\":\"Echo\",\"@id\":\"https:\\\/\\\/oretonstorage.com\\\/#\\\/schema\\\/person\\\/691da96ccdd2a899702e96be4c0b892e\"},\"headline\":\"SSD Write Amplification and NAND Flash Endurance\",\"datePublished\":\"2026-08-11T07:38:38+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/oretonstorage.com\\\/blog\\\/ssd-write-amplification-and-nand-flash-endurance\"},\"wordCount\":1274,\"image\":{\"@id\":\"https:\\\/\\\/oretonstorage.com\\\/blog\\\/ssd-write-amplification-and-nand-flash-endurance#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/oretonstorage.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/BCO.82ef9134-0979-4620-b8e8-122bdc3088a0.png\",\"articleSection\":[\"Blog\"],\"inLanguage\":\"ko-KR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/oretonstorage.com\\\/blog\\\/ssd-write-amplification-and-nand-flash-endurance\",\"url\":\"https:\\\/\\\/oretonstorage.com\\\/blog\\\/ssd-write-amplification-and-nand-flash-endurance\",\"name\":\"SSD Write Amplification and NAND Flash Endurance -\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/oretonstorage.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/oretonstorage.com\\\/blog\\\/ssd-write-amplification-and-nand-flash-endurance#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/oretonstorage.com\\\/blog\\\/ssd-write-amplification-and-nand-flash-endurance#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/oretonstorage.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/BCO.82ef9134-0979-4620-b8e8-122bdc3088a0.png\",\"datePublished\":\"2026-08-11T07:38:38+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/oretonstorage.com\\\/#\\\/schema\\\/person\\\/691da96ccdd2a899702e96be4c0b892e\"},\"description\":\"Explore SSD write amplification, NAND flash endurance, garbage collection, wear leveling, over-provisioning, and the role of controllers and firmware in SSD reliability.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/oretonstorage.com\\\/blog\\\/ssd-write-amplification-and-nand-flash-endurance#breadcrumb\"},\"inLanguage\":\"ko-KR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/oretonstorage.com\\\/blog\\\/ssd-write-amplification-and-nand-flash-endurance\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/oretonstorage.com\\\/blog\\\/ssd-write-amplification-and-nand-flash-endurance#primaryimage\",\"url\":\"https:\\\/\\\/oretonstorage.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/BCO.82ef9134-0979-4620-b8e8-122bdc3088a0.png\",\"contentUrl\":\"https:\\\/\\\/oretonstorage.com\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/BCO.82ef9134-0979-4620-b8e8-122bdc3088a0.png\",\"width\":1536,\"height\":1024},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/oretonstorage.com\\\/blog\\\/ssd-write-amplification-and-nand-flash-endurance#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/oretonstorage.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Blog\",\"item\":\"https:\\\/\\\/oretonstorage.com\\\/blog\\\/category\\\/blog\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"SSD Write Amplification and NAND Flash Endurance\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/oretonstorage.com\\\/#website\",\"url\":\"https:\\\/\\\/oretonstorage.com\\\/\",\"name\":\"\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/oretonstorage.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ko-KR\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/oretonstorage.com\\\/#\\\/schema\\\/person\\\/691da96ccdd2a899702e96be4c0b892e\",\"name\":\"Echo\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ko-KR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9970439d619162f7823db50b8a803904cf5d449a40abe89abee48df8ed6fdad?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9970439d619162f7823db50b8a803904cf5d449a40abe89abee48df8ed6fdad?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/c9970439d619162f7823db50b8a803904cf5d449a40abe89abee48df8ed6fdad?s=96&d=mm&r=g\",\"caption\":\"Echo\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"SSD Write Amplification and NAND Flash Endurance -","description":"Explore SSD write amplification, NAND flash endurance, garbage collection, wear leveling, over-provisioning, and the role of controllers and firmware in SSD reliability.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/oretonstorage.com\/ko\/\ube14\ub85c\uadf8\/ssd-write-amplification-and-nand-flash-endurance","og_locale":"ko_KR","og_type":"article","og_title":"SSD Write Amplification and NAND Flash Endurance -","og_description":"Explore SSD write amplification, NAND flash endurance, garbage collection, wear leveling, over-provisioning, and the role of controllers and firmware in SSD reliability.","og_url":"https:\/\/oretonstorage.com\/ko\/\ube14\ub85c\uadf8\/ssd-write-amplification-and-nand-flash-endurance","article_published_time":"2026-08-11T07:38:38+00:00","og_image":[{"width":1030,"height":687,"url":"https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/08\/BCO.82ef9134-0979-4620-b8e8-122bdc3088a0-1030x687.png","type":"image\/png"}],"author":"Echo","twitter_card":"summary_large_image","twitter_misc":{"\uae00\uc4f4\uc774":"Echo","\uc608\uc0c1 \ub418\ub294 \ud310\ub3c5 \uc2dc\uac04":"7\ubd84"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/oretonstorage.com\/blog\/ssd-write-amplification-and-nand-flash-endurance#article","isPartOf":{"@id":"https:\/\/oretonstorage.com\/blog\/ssd-write-amplification-and-nand-flash-endurance"},"author":{"name":"Echo","@id":"https:\/\/oretonstorage.com\/#\/schema\/person\/691da96ccdd2a899702e96be4c0b892e"},"headline":"SSD Write Amplification and NAND Flash Endurance","datePublished":"2026-08-11T07:38:38+00:00","mainEntityOfPage":{"@id":"https:\/\/oretonstorage.com\/blog\/ssd-write-amplification-and-nand-flash-endurance"},"wordCount":1274,"image":{"@id":"https:\/\/oretonstorage.com\/blog\/ssd-write-amplification-and-nand-flash-endurance#primaryimage"},"thumbnailUrl":"https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/08\/BCO.82ef9134-0979-4620-b8e8-122bdc3088a0.png","articleSection":["Blog"],"inLanguage":"ko-KR"},{"@type":"WebPage","@id":"https:\/\/oretonstorage.com\/blog\/ssd-write-amplification-and-nand-flash-endurance","url":"https:\/\/oretonstorage.com\/blog\/ssd-write-amplification-and-nand-flash-endurance","name":"SSD Write Amplification and NAND Flash Endurance -","isPartOf":{"@id":"https:\/\/oretonstorage.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/oretonstorage.com\/blog\/ssd-write-amplification-and-nand-flash-endurance#primaryimage"},"image":{"@id":"https:\/\/oretonstorage.com\/blog\/ssd-write-amplification-and-nand-flash-endurance#primaryimage"},"thumbnailUrl":"https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/08\/BCO.82ef9134-0979-4620-b8e8-122bdc3088a0.png","datePublished":"2026-08-11T07:38:38+00:00","author":{"@id":"https:\/\/oretonstorage.com\/#\/schema\/person\/691da96ccdd2a899702e96be4c0b892e"},"description":"Explore SSD write amplification, NAND flash endurance, garbage collection, wear leveling, over-provisioning, and the role of controllers and firmware in SSD reliability.","breadcrumb":{"@id":"https:\/\/oretonstorage.com\/blog\/ssd-write-amplification-and-nand-flash-endurance#breadcrumb"},"inLanguage":"ko-KR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/oretonstorage.com\/blog\/ssd-write-amplification-and-nand-flash-endurance"]}]},{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/oretonstorage.com\/blog\/ssd-write-amplification-and-nand-flash-endurance#primaryimage","url":"https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/08\/BCO.82ef9134-0979-4620-b8e8-122bdc3088a0.png","contentUrl":"https:\/\/oretonstorage.com\/wp-content\/uploads\/2026\/08\/BCO.82ef9134-0979-4620-b8e8-122bdc3088a0.png","width":1536,"height":1024},{"@type":"BreadcrumbList","@id":"https:\/\/oretonstorage.com\/blog\/ssd-write-amplification-and-nand-flash-endurance#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/oretonstorage.com\/"},{"@type":"ListItem","position":2,"name":"Blog","item":"https:\/\/oretonstorage.com\/blog\/category\/blog"},{"@type":"ListItem","position":3,"name":"SSD Write Amplification and NAND Flash Endurance"}]},{"@type":"WebSite","@id":"https:\/\/oretonstorage.com\/#website","url":"https:\/\/oretonstorage.com\/","name":"","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/oretonstorage.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ko-KR"},{"@type":"Person","@id":"https:\/\/oretonstorage.com\/#\/schema\/person\/691da96ccdd2a899702e96be4c0b892e","name":"\uc5d0\ucf54","image":{"@type":"ImageObject","inLanguage":"ko-KR","@id":"https:\/\/secure.gravatar.com\/avatar\/c9970439d619162f7823db50b8a803904cf5d449a40abe89abee48df8ed6fdad?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/c9970439d619162f7823db50b8a803904cf5d449a40abe89abee48df8ed6fdad?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/c9970439d619162f7823db50b8a803904cf5d449a40abe89abee48df8ed6fdad?s=96&d=mm&r=g","caption":"Echo"}}]}},"_links":{"self":[{"href":"https:\/\/oretonstorage.com\/ko\/wp-json\/wp\/v2\/posts\/4613","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/oretonstorage.com\/ko\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/oretonstorage.com\/ko\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/oretonstorage.com\/ko\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/oretonstorage.com\/ko\/wp-json\/wp\/v2\/comments?post=4613"}],"version-history":[{"count":3,"href":"https:\/\/oretonstorage.com\/ko\/wp-json\/wp\/v2\/posts\/4613\/revisions"}],"predecessor-version":[{"id":4618,"href":"https:\/\/oretonstorage.com\/ko\/wp-json\/wp\/v2\/posts\/4613\/revisions\/4618"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/oretonstorage.com\/ko\/wp-json\/wp\/v2\/media\/4615"}],"wp:attachment":[{"href":"https:\/\/oretonstorage.com\/ko\/wp-json\/wp\/v2\/media?parent=4613"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/oretonstorage.com\/ko\/wp-json\/wp\/v2\/categories?post=4613"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/oretonstorage.com\/ko\/wp-json\/wp\/v2\/tags?post=4613"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}